The SIS2 intelligent Level Switch is compatible with many materials and is used for high or low alarm and materials block detection in production process tank or pipelines. Compact design with PEEK tip facilitates installation in narrow spaces and many applications with an IP67 rating. Suitable for use in CIP cleaning, pharmaceutical and food & beverage processing applications. The SIS2 is not affected by viscous or paste like medium attached on sensor. Equipped with Magnetic test function to check operation condition in real time, LED indicator light and two outputs NO/NC. One sensor for all your applications need – feeds, grains, ketchup, sauce, coffee powders, flour, creamer powder, ketchup, mayonnaise, honey, yoghurt and toothpaste.

Applications
Features
Specifications
Literature

The SIS2 intelligent Level Switch is compatible with many materials and is used for high or low alarm and materials block detection in production process tank or pipelines. Compact design with PEEK tip facilitates installation in narrow spaces and many applications with an IP67 rating. Suitable for use in CIP cleaning, pharmaceutical and food & beverage processing applications. The SIS2 is not affected by viscous or paste like medium attached on sensor. Equipped with Magnetic test function to check operation condition in real time, LED indicator light and two outputs NO/NC. One sensor for all your applications need – feeds, grains, ketchup, sauce, coffee powders, flour, creamer powder, ketchup, mayonnaise, honey, yoghurt, toothpaste, Starch, Cocoa Powder, Hazelnut Powder(40C), Pepper (Ground), Mashed Potatoes, Creamer (Powder), Salt, Caster Sugar and Crystal Sugar (Ground).

  • Easy installation by standard connection with IP67 as protection grade.
  • Compact design, easy carry; can be installed in narrow space or stringent operation condition.
  • Probe material PEEK surface roughness Ra<0.8 is with good wear resistance.
  • Magnetic test function to examine wiring and operation condition in real time.
  • Real time site-control by local LED indicators.
  • Durable stainless housing.
  • Overcurrent protection detects over current and shut down the output immediately.
  • Workable in CIP cleaning environment.
  • 2 output signals NPN or PNP.
  • Suitable for dry running protection and single point level detection of powder or granular medium in containers or pipelines.
  • Process Temperature: -40~100℃(-40~212℉)
  • Process Pressure: -1~40 bar.
  • Operating Voltage: 12VDC~30VDC
  • Switch Output: 2 switches: 1st NO mode and 2nd NC mode.
  • Overvoltage protection category II
  • Short-circuit protection and overload protection.
  • Electrical Connection: M12 4PIN connector
  • Probe material/Surface roughness: PEEK/Ra<0.8
  • Local Indicator: Yellow LED for starting, Green LED for resetting.